− | The following page provides some supplemental information for the '''RC Circuits and Filtering''' lab for [[EGR 224|EGR 224L]]. It has been updated for Spring, | + | The following page provides some supplemental information for the '''RC Circuits and Filtering''' lab for [[EGR 224|EGR 224L]]. It has been updated for Spring, 2019. |
== Clarifications == | == Clarifications == | ||
* If any of your figures looks wrong, it probably is! Be sure to have a TA check your figures so that you leave the lab with a valid data set. | * If any of your figures looks wrong, it probably is! Be sure to have a TA check your figures so that you leave the lab with a valid data set. | ||
+ | * Use MATLAB on the PC to do the data acquisition | ||
+ | * For newer versions of MATLAB (2015 and after), the proper way to get out of a "keyboard" environment is to type the word "dbcont" and hit enter; the word "return" no longer works for that | ||
+ | * For Maple, when you put in the sinusoid at 60 rad/s, Maple may try to be "helpful" and use double angle formula to come up with a result that is a complete mess; try a frequency of 60.01 rad/s instead. It's just about the same speed and Maple won't be...helpful... | ||
+ | * The experimental phase values should track well at low frequencies but may fluctuate a bit at higher frequencies due to inaccuracies in determining peaks. | ||
== Element Values == | == Element Values == | ||
Line 42: | Line 46: | ||
Click on the pictures above to make them larger. | Click on the pictures above to make them larger. | ||
− | + | == Voltage Images == | |
+ | <gallery> | ||
+ | File:Data 0001 12 clean.jpg|Clean graphs indicating good wiring | ||
+ | File:Data 0001 12 fuzzy.jpg|Fuzzy graphs indicating wiring problems | ||
+ | </gallery> | ||
[[Category:EGR 224]] | [[Category:EGR 224]] |
Latest revision as of 18:35, 19 March 2019
The following page provides some supplemental information for the RC Circuits and Filtering lab for EGR 224L. It has been updated for Spring, 2019.
Clarifications
- If any of your figures looks wrong, it probably is! Be sure to have a TA check your figures so that you leave the lab with a valid data set.
- Use MATLAB on the PC to do the data acquisition
- For newer versions of MATLAB (2015 and after), the proper way to get out of a "keyboard" environment is to type the word "dbcont" and hit enter; the word "return" no longer works for that
- For Maple, when you put in the sinusoid at 60 rad/s, Maple may try to be "helpful" and use double angle formula to come up with a result that is a complete mess; try a frequency of 60.01 rad/s instead. It's just about the same speed and Maple won't be...helpful...
- The experimental phase values should track well at low frequencies but may fluctuate a bit at higher frequencies due to inaccuracies in determining peaks.
Element Values
- Resistances:
- 1, 9, 17: 2.2 k\(\Omega\)
- 2, 3, 10, 11, 18, 19: 4.7 k\(\Omega\)
- 4, 5, 12, 13, 20, 21: 10 k\(\Omega\)
- 6, 14, 16, 22: 15 k\(\Omega\)
- 7, 8, 15, 23, 24: 22 k\(\Omega\)
- Capacitances
- 7, 15, 23: 2.2 \(\mu\)F
- 4, 6, 8, 12, 14, 16, 20, 22, 24: 4.7 \(\mu\)F
- 2, 5, 10, 13, 18, 21: 10 \(\mu\)F
- 1, 3, 9, 11, 17, 19: 22 \(\mu\)F
Links
- The MATLAB:Transfer Functions page should be very helpful here.
- The files for this assignment can be downloaded from http://classes.pratt.duke.edu/FILES/EGR224/DAQS/RCfilter
- See Transferring_Files for information on how to get the files to your CIFS space.
Wiring Images
Closeup of the CB-68LP